Showing posts with label science. Show all posts
Showing posts with label science. Show all posts

Sunday, October 29, 2023

ProteoCool #Pills29: Simple solutions to improve laboratory routine work with few euro/dollars: #1 IKEA


Chain stores with furniture, DIY, decoupage hobbies as 

IKEA, OBI, Leroy Merlin, Bricoman 

 can be a great source for funny and cheap items useful for improve the laboratory organization

Here i report just some examples: 

1) SANDVIVIA OVEN MIT 

                   made in silicone which provides a firm grip and is heat-insulating.

It allow to manipulate and move the hot agarose gel and/or hot culture media removed from microwaves or autoclave.

                                           Avaialble from IKEA (Italy: 3euro - US: 4 dollars )

-----------------------------------------------------------------------------------------------------------------------------

2) VEKSEN CART 

It fits in the smallest of laboratory, but there’s plenty of space on the shelves for all  for all those staff that you need to have on hand when you work on the laminar hood

             or in a laboratory with low space 



Assemble the trolley quickly and easily by clicking the parts together without any specific tools.

Available from IKEA (Italy: 10 euro;  US: 9 dollars) 

----------------------------------------------------------------------------------------------------------------------------

TIKSEN Hook with suction cup.

Alternative clothes hanger solution

Available from IKEA (Italy: 7euro/4p; US: 5dollars/2p) 

......................................................................................................................................................................

                                                                    BEVARA Sealing clip. 

                                                       Cheap clips for use with Dialysis Tubing 

                                         Available from IKEA (Italy 1,5euro/10p: US: 2 dollars/10p ) 




Monday, June 5, 2023

ProteoCool Pills#27: DSF an useful tool for Monoclonal antibodies selection, optimization and developabiltiy assesment

 

DSF 

(Differential scanning fluorimetry previously named also Thermofluor)

is a very simple tecniques that exploit the ability of a fluorescente probe,  typically either SYPRO Orange or 1-anilino-8-naphthalenesulfonate (ANS) – that is quenched in an aqueous environment but becomes strongly fluorescent when bound to exposed hydrophobic groups of a protein. Therefore, the thermal unfolding of a protein of interest in the presence of such a dye, can be followed spectrophotometrically.

DSF is a 96 well based assay that could be performed on a RT-PCR thermocycler, it is inexpensive,  fast, and require relatively little sample. All these advantages have made this approach attractive for screening applications in drug discovery  and also for protein stability formulation

In the ProteoCool n°24 in suggest as in my opinion the DSF may become an essential assay todetermine lot to lot concistenciy in QC department of company producing recombinant proteins (e.g recombinant vaccine and/or enzymes)

In this post i would like to share with you 2 examples that show as DSF may play an important role also in antibody screening, optimization and developability assesment. 

DSF thanks to its excellent throughput and minimal material consumption (about 50ul of antibody at 0,3 mg/ml for each point) allow to readily compare the thermal stability of:

- different antibodies in the same buffer:

-  different  Fab mutants or Fc mutants in the same buffer;

-  different  antibody formulations; (optimize pH, salt concentration, excipients)


Example 1: 

Comparision of thermal stability of different mabs 

Full length human IgG1-Clk mabs  in PBS may show 1 or 2 separate transitions on the basis of the Fab stability. 

Mabs with lower Fab stability show in general a single transition while mabs with high stability show 2 separate transitions, 1 at about 69°C for the Fc and 1 at higher temperature for the Fab.


Example 2:

Comparision of thermal stability of different Fc mutants

In recent years the enhancement or elimination of the Fc-effector function has led to a growing interest in Fc-engineering, to give antibodies specific mechanisms of action and therapeutic properties.  

Even if several Fc modification, as:

-   LALANA, LALAPG, LALAGR mutations to remove effector function;

-  SDIE, GAALIE mutations as well as afucosilation to enanche the effector function

 were already reported, few data about developability of those solutions are still available and there is a lot work  to do to select an enanched Fc combining the best effector function and good manufacturability, stability and pharmacokinetics.

Those are just 2 examples that show as in short time and using a limited amount od samples, thanks to DSF we can obtain  essential informations to guide our decision in antibody during the screening, desing, formulation phases.

Of course, thermal stability itself do not Guarantee that the selected antibody has good developability profile but  some of the following other tecniques as:

- DLS;

- PEG solubility;

- Self-interaction determined by BLI;

those provide informations about antibody  aggregation propensity 

- Hydrofobic interaction chromatografy (HIC)

those provide informations about antibody hydrofobicity

have to be peformed to complement the DSF data. 


A great thanks  to

 Luca Sorrentino





 

Wednesday, May 3, 2023

ProteoCool Pills#26: Guidelines to download a Video from blogger sites

 In the Video Section of ProteoCool are actually available more than 30 different video tutorials about molecular biology, protein expression and characterization. 

All those video can be easily downloaded using the Video DownloadHelper tool available on Mozilla Firefox browser.  No cost or restriction are associated to the ProteoCool video use or sharing. 

I just ask you to cite, ProteoCool, in case you will share or use part of it for build new material. 

In this post I would like to show you, how video download from a Blog (not only PRoteoCool but all the blogger.com blogs is possible using the Mozilla browser

How yu can do it: 

- Open Mozilla Firefox browser; 

- Check if the Video DownloadHelper is already installed in your browser

The presence of the Video DownloadHelper is identified by the presence of an Icon that shows 3 balloons (in gray scale) located on the Firefox toolbar.  

If Video DownloadHelper is already installed, you can choose your video and download it in few minutes following few steps: 

1. Access to the blog from which you would like to download the video (e.g. PRoteoCool)


In case that the Video DownloadHelper is not present in your browser, you can download it:


-                 Click on the VideoDownload helper icon and proceed with the installation by

               following the different instructions.


-              Once the 3 balloon icon will appear on the top of your browser, Downloading videos 

                from the Blogger site is now possible.  

                Go to the step 1  

Monday, April 3, 2023

ProteoCool Pills#25: Choice of the right material is essential to perform DNA and/or protein UV Spectrophotometric quantifications

 As already reported in the ProteoCool Pills#13, and ProteoCool Pills #24 several different methods are currently available to perform quantification of purified DNA fragments and plasmid as well as recombinant proteins and antibodies.

One simple method common to both, DNA and protein quantification is the spectrophotometric determination in the UV range (260nm for DNA and RNA and 280nm for proteins and monoclonal antibodies)

Spectrophotometric quantification has several advantages:

 - Cheap (do not require any specific reagent);

-  Fast (do not require sample pre-incubations);

- Non-destructive (the sample could be recovered);

The main drawback that limits in the past the use of the UV quantification was the fact that standard glass and standard plastic absorbs strongly in UV region and the quartz cuvettes were necessary to perform protein (280nm) and DNA (260nm) quantification.

Quarts cuvettes work well in both UV and visible regions (right from 190 nm) but are expensive, fragile and time consuming, because not disposable and therefore it need to be carefully washed between the different samples.

Of course the same limitation is applicable also to the multiplate reader, because the standard plastic bottom plates cannot be used for measurements in <300-320 nm due to the plastic absorbance.

Solutions:

1) Use a microvolume UV-Vis spectrophotometers (eg Nanodrop) that do not require any specific support (plate or cuvette):

  Pros:

 Low sample volume (2 µl)

 Fast

      Simple

       Cons:

          Less sensitive than cuvettes because the optical path is 1mm instead 10mM of the cuvettes

  Lambert-beer law à  Abs=ebc where b is the optical path

For the same sample e= constant à 1/10 of optical path à 1/10 of Abs at the same c (concentration)

 Need to be carefully cleaned (protein buffers are rich of salt and the surface properties of the pedestals can be compromised and the samples drop Flattens out and the read are not reproducible

       2) Use Plastic UV-Cuvette or  UVclear multiplates:

In the recent years special plastic compounds with low absorbance at wavelength >220nm were developed:

In this post I would like just to provide some example of comparision of background Abs260 and Abs280 signal obtained with standard and UV-transparent plastic matherial:


In conclusion, expecially for DNA determination, standard plastic cuvette and multiwell plates cannot be used. The UV transparent plastics represent a nice, cheaper alternative to quartz cuvette. If it is true that those support are little more expensive than the corresponding made by standard plastic matherial, it is also true that in the most of the cases, after carefull washing with milliQ water and ethanol20%  can be re-used many times. 


 

Thursday, March 9, 2023

ProteoCool pills#24: Rapid fluorimetric DNA plasmid quantification on 96 welll plate

One of the most common methods for nucleic acid detection and quantification is the measurement of solution absorbance at 260 nm (A260) due to the fact that nucleic acids have an absorption maximum at this UV wavelength

When DNA is present in the sample a fraction of the ultraviolet light will pass through and an other fraction will be absorbed and the amount of the light absorbed is directly proportional to the nucleic acid concentration in the sample. Using the Beer-Lambert Law it is possible to relate the amount of light absorbed to the concentration of the absorbing molecule.

At a wavelength of 260nm, the average extinction coefficient is:

-        0.020 (μg/ml)−1cm−1, double-stranded DNA;

-        0.027 (μg/ml)−1 cm−1, for single-stranded DNA 

Spectrophotometric quantification is precise and with the advent of microvolume spectrophotometer (e.g  nanodrop) those allow to perform measurement using very small sample volumes (1-2ul) with-out the use of any sample support (e.g quartz cuvette)  it become the method of first choice for DNA plasmid quantification in the molecular biology laboratories.

DNA quantification with microvolume spectrophotometer is precise and allow to evaluate DNA purity and RNA but it is time consuming  (20-30’’ for sample) and therefore not applicable to the measurement of a huge number of samples in parallel.

Modern HT (High throughput) cloning platforms produce hundreds of DNA samples (plasmidic ans/or genomic) in parallel and using a multiwell based approach is certainly preferable to speed up the process. 

Since multiwell determination require at least 50-100 ul of  sample/well,  a preliminary sample dilution step is required to do not use the entire DNA sample for this step, but this may represent a problem, since the method sensitivity is limited.

For example: 

- If we consider that A(260)=0.1 using a spectrophotometer with 1 cm of optical path-lenght correspond to a dna sample with concentration of 5ng/ul. 

Generally the path-length in a multiwell plates is lower than 1cm 

For example 100ul of an half area UVclear 96 well plate result on a path length of about 0,67cm  (A(260)=0,1 with a 7,5ng/ul sample)

Therefore if we dilute 10ul of our MINI PREP to 100ul final and we read the ABS280 on a multiplate reader we will obtain a  detectable ABS (>0,1) only for samples with concentration >75ng/ul that is too high since in my experience the range of plasmid concentrations that are generally obtained with a 96 well plate mini kit is in the range 20-100ng/ul. 

In this post I would like to show you as using a common Fluorimetric stains  (in my case Lonza Gel Star) developed to bind DNA staining in agarose gel a rapid DNA quantification could be performed in 96 well plate format. 

Example:

DNA plasmidic quantification using Gel Star probe (Lonza)

2ul DNA sample in 100ul Gelstar stain diluted 10000 times (1X final concentration) in H2O 

plates: 96 well flat black (Greiner)


Instrument: multiplate reader (Tecan M200)   Ex:490nm; Em:530mn (gain:80)

A standard curve was built using an available commercial plasmid pRSET/BFP (Invitrogen) and serial dilution were performed to obtain a final DNA concentration range (2,5- 0,0025ug/ml) 


The fluorimetric methods using GelStar show linearity in a concentration range 0,01ng/ul to 0,625ng/ul.

Therefore the methods, using 2ul of dna sample (dilute in 100 of probe) could be direclty applied to the quantification of DNA samples in concentration range 0,5-30 ng/ul that is in the range of the sample that normally are obtained for 96-well mini kit dna preparation kit.

In case that DNA samples are more concentrated we can simple reduce the DNA volumes  (to 1ul or 0,5ul) used for the test.

Considering that fluorescence of the probe can depend from DNA size and origin (single or double strand) is it ever suggested to perform a calibration line with a standard DNA sample with similar size and origin respect the ones that we would like to quantify.

Of course differently to 260/280 nm quantification this methods do not allow to you to estimate sample purifity )in terms of protiens) or buffer contamination but i'm my opinion modern mini kits are quite reilable and in 99% of cases the sample quality is ok for the downstream applications (eg sequencing, E.coli trasformation)

In my experience, this method is very usefull to rapid quantification of high number of purified plasmid to use for sequencing, trasformation and protein expression. 

I have done those trials with GelStar probe since it was the one avaialble in my lab at the time of this test but i suppose that similar results can be obtained also with other simiilar probes (eg, Gelred, midori green, Sybr safe it the right Ex/Em wavelenght were selected. Since each probe is chatacterized from a different fluoresence quantum yielad is possible that a different probe may affect a little the limit of sensitivity. 

Please, DO NOT USE Ethidium Bromide!!

Fortunatelly today,  less toxic probes (as i already mentioned in the ProteoCool Pills n°4) with similar sentitivity and low cost are avaialble. 



Monday, November 7, 2022

ProteoCool Pills#21: Chromas a free tool to check your Sanger sequencing results

In the last 20 years several different software packages able to support the scientist in their molecular cloning activities  (e.g primer desing, sequence assembly, transaltiion, vector desing  desing to manipulate DNA and protein sequences  as CloneManager, SnapGene, VectorNTI (discontinued by Thermo from 2019)

Those software are fully integrated set of tools for e cloning simulation, graphic map drawing, primer design and analysis. They are charaterized by a huge number of functions and they require the payment of a licence. 

Are those advanced softwares striclty necessary for a molecular biologist that would like just to check the result of a gene cloning into a mammalian or bacterial expression vector ?

In my opinion NO! 

Those softwares could be certanilly useful (for example to map the primer annealing region, to desing the vector map) but not essential expecially if you have to produce a limited number of clones in parallel.

For example, in this post i would like to present youm  Chromas, which  is a free simple, easy-to-use sequence viewer and editor (able to open chromatogram files(.ab1) produced from automated Sanger sequencers) that could be used to check your sequencing results.

7A. Allign the Chormas sequence with the “Theoretical” DNA template 
or 
7B. Translate the sequence in AA format 
 (Generally I’m using the Translate Tool available at the Expasy web server) 
and allign the translated sequence with the “theoretical AA” template

If the sequence show some point mutation or shift, do not  discard the clone but check carefully the chromatogram to see if the mutation/shift is real or is it due to a non-correct Chromas assignment that may happen in case of:
-  overlapping peaks:
- peak with low intensity;
- a sequence regions with multiple residues of the same species;
  
Other similar softwares:


Friday, November 26, 2021

ProteoCool Pills#14: Hints for cell propagation and recombinant protein expression using Expi-CHO and Expi293 (WT and GNTI-)

For many years the application of the traditional adherent mammalian cell cultures for recombinant protein production was difficult and applicable only in those approaches requiring very low protein amount (ug’s) because cell scale up was very difficult, transfection not very efficient and the final volumetric yields (mg/litre) very low. 

This limitation forces the scientist to use other simple eukaryotes expression systems as Pichia Pastoris or Baculo virus for the production of mammalian protein in mg scale.

However, in the last 20 years some technological improvements as:

 1) The adaptation of several cell lines to suspension cultures;

 2) The development of more efficient transfection agents;

 3) The development of serum free media where the cells are able to growth at high cell density;

Improve drastically the performances of the mammalian expression systems;

As I already mention in previous presentations, theExpi293 and Expi-CHO date, represent 2 of the most performing mammalian transient expression systems. 

If it is true that those systems are quite expensive, on the other hand they are very simple to use and guarantee, high yields also in shake flask. 

For some recombinant protein, Expi293 in shake flask were able to provide me up 300mg/yields. 

Values that until some years ago were reachable only using E. coli expression in high cell density set-up (e.g. feed-batch fermenters)

Expi-CHO are able to provide up to 100-200 mg/l of full length recombinant antibodies. Full length antibodies are big (150KDa), composed from 2 chains and contains several disulfide bonds, their expression in bacterial expression system is very challenging.

However, to reach those results details, as;

-             - The selection of the optimal shake flask format and right culture volume;

-              -  The selection of an antibiotic not affecting cell growth and protein expression;

-                The selection of the optimal signal peptide for protein secretion into the cell surnatant;

can make a huge difference!!

The selection of the right shake flask and culture volume

Expi293F and Expi293 GNT- cells :

In small scale (up to 60ml culture) Expi293 are not so sensitive to the flask format and presence of baffle:

For example, in our experience Expi293 are growing well in both

-        Erlenmeyer flaskscup vented plain (cost ~ 8€/flask for 125ml format)

-        Erlenmeyer flasks cup vented baffled

-        Thomson Optimun growth flaks  (cost ~ 8€/flask for 125ml format and 30€/flask for 1,6l)

Optimal culture volumes: 

125ml flask volume for 30ml Expi293 transfection and 250ml flask volume for 60ml Expi293 transfection

For culture scale up (eg 200-500ml culture),  the Thomson Optimun growth flaks eems to perform better probably  because it guarantee better CO2 and oxygen exchange.

My preferred format is 200-300ml transfection in 1.6liter flask and generally we do not exceed the 500ml single transfection (using a 2.4 litre flask) because in high volumes we more frequent bacterial contamination was observed, therefore in case of large culture volume e.g. 1-2liter, I prefer to split the culture using more flask in parallel.

ExpiCHO:

ExpiCHO show an high tendency to aggregate and are much more susceptible to  the flask format.

Thomson Optimun growth flaks https://htslabs.com/og/ that contain small baffles seem to represent the best compromise and are the format more able to prevent the cell aggregation during the cell maintenance passages.

N.B: Expi-CHO are able to growth up to very high cell density (>10milion/ml) but to avoid cell aggregation is it better do not exceed the 6 milion/ml during the cell propagation passages

Optimal culture volumes: 

   125ml flask for 25ml transfection 

   250ml flask for 50 ml trasfection

    1,8liter flask for 150-300ml tranfection

In all cases we use the max titer protocol à 8day of trasfection at 32°C

The selection of the right antibiotics to prevent cell contamination.

The Expi293 and ExpiCHO Thermofisher manuals do not suggest the addition of any antibiotics to prevent bacterial contaminations. However after that we experienced some culture contaminations, considering the high  cost of the reagents (more than 1000euro/Liter)  we decided to perform some  transfection trials in the presence of  antibiotics to see if they affect or not the cell viability, growth rate and recombinant protein expression

Expi293 are not affected by:

-        Pen/strep (thermo cod. 15070-063) diluted 1:100 (50 unit/ml penicillin and 50ug/ml Streptomycin)  

-        Gentamicin (Sigma cod. G1272) diluted 1:200 (50ug/ml)

Generally, we use for cell propagation and transfection the Pen/Strep 

Expi293 GNT- are not affected by Gentamicin (Sigma cod. G1272) diluted 1:200 (50ug/ml) while reduction in cell growth rate and viability was observed in presence of Pen/Strep;

Expi-CHO are not affected by Pen/strep (thermo cod. 15070-063) diluted 1:100 while reduction in cell growth rate and viability was observed in presence of Gentamicin diluted 200 times.

 

 

 

 

 

ProteoCool37: Densitometric analisys of SDS-page using Image LAB software (license free version)

  A new video exploring how to optimize the densitometric analysis of SDS-PAGE gels using the basic version of Bio-Rad Image Lab is now avai...